Error code list and trouble shooting

Code Description Trooble shooting
Location 1: WebC errors
10 Communication errors
10:01 No communication
10:02 Checksum error
10:03 Bad quality of the data stream
10:04 bad quality of bytes
11 Communication errors
11:01 No communication
11:02 Checksum error
11:03 Bad quality of the data stream
11:04 bad quality of bytes
Location 2: Fan Folder errors
21 Error on stepper control boards
21:01 Error on starting stepper control board
21:02 Error on stopping stepper control board
22 Sensor errors on start-up
22:00 Sensor LB0 cut
22:01 Sensor LB1 cut
22:02 Sensor LB2 cut
22:03 Sensor LB3 cut
22:04 Sensor LB4 cut
23 Sensor sends high level permanently
23:00 Sensor LB0
23:01 Sensor LB1
23:02 Sensor LB2
23:03 Sensor LB3
23:04 Sensor LB4
24 Processing errors on stepper control boards
24:01 Error while calculating the step
24:02 Error while counting the steps
25 hardware errors
25:01 Lack of 5 Volts external
25:02 Lack of 38 Volts in FF or CF door open
25:03 Cover open
26 Time out errors
26:01 No ready signal after paper cut
26:02 No paper at sensor LB1 after paper cut
26:03 No paper at sensor LB1 without cut signal
26:04 Jam between sensors LB0 and LB1
26:05 No trailing edge of the paper at sensor LB1
26:06 Too many folds, document is too long
26:07 No trailing edge of the paper at sensor LB0
26:08 Unexpected paper at sensor LB4 in Online-Mode
26:09 Unexpected paper at “no fold” switch LB5 in Online-Mode
Location 3: Cross Folder errors
80 Hardware errors
80:01 Lack of 5 Volts external
80:02 Lack of 38 Volts in FF or CF door open
80:03 Lack of 28 Volts
81 Error on stepper control boards
81:01 Error on starting stepper control board
81:02 Error on stopping stepper control board
82 Sensor errors on start-up
82:01 Sensor LB12 cut
82:03 Sensor LB10 cut
82:04 Sensor LB13 cut
83 Sensor sends high level permanently
83:01 Sensor LB12
83:02 Sensor LB11
83:03 Sensor LB10
83:04 Sensor LB13
84 Time out errors
84:01 Sensor LB11
84:02 Sensor LB12
84:03 Sensor LB13
84:04 Paper did not reach the CF exit switch
84:05 Jam at CF exit switch
84:06 Jam at sensor LB10
85 Paper jam
85:01 Jam at sensor LB11
85:02 Jam at sensor LB12
86 Error at roll tray motor end stage
86:01 Error while moving forward
86:02 Error while moving backward
86:03 Error while trying to stop
86:04 Error during initialisation
Location 4: Tab Applicator
41:01 Tab unit is not ready
41:02 Error at motor end stage
41:03 No tape inside the unit or sensor is damaged
41:04 Jam close to the knife
Errors in modules
01xx... In any case the code atarts with 01 check the sensors in diagnostics
02 Initialisation error
03 Error on linear activator

Module 1: Stacking unit
02 Initialisation error

Module 2: Tab application unit
01 0x01 Switch in position 198mm or 11 inches
01 0x02 Switch in position 210mm or 12 inches
02 Initialisation error
Communication error between WebC and modules
20:xx WebC and Module 0
21:xx WebC and Module 1
22:xx WebC and Module 2
23:xx WebC and Module 3
xx:01 No communication
xx:02 Checksum error
xx:03 Bad quality of the data stream
xx:04 bad quality of bytes
F1CA CAN-bus error